As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
ROW 8 OVERHEAD EMERGENCY LIGHT INOP. REF MEL 33-08 AUTH# 091340D-C LOG PG 5176395/1 PERFORMED VOLTAGE CHECK OF CONNECTOR P0388 IAW WM 33-50-50-1 AND SWPM 20-64-00. NO VOLTAGE WAS RECEIVED BETWEEN PINS C TO D AND C TO H. RAR THE FWD #2 ELPU IAW AMM 33-50-01. OPS CHECK GOOD AND NO FURTHER DEFECTS NOTED. MEL ITEM 33-8 IS RESTORED.