Service difficulty report · Shunt · Emb ERJ170200LR

Difficulty date
May 5, 2025
Submitted
May 6, 2025
Operation
Air carrier
Aircraft
N250NN
Make and model
Emb ERJ170200LR
Aircraft serial
17000635
Aircraft time
21,275 hours, 14,241 cycles
Part
Shunt
Condition
Faulted
Location
Bleed Air Sys
Stage of operation
NR
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLEED 1 OVRPRSS. ATC DECLARED EMERGENCY. RETURN TO DFW. ACCOMPLISH PER ERJ WC 36-11-03-001. NAPRSOV VALVE FILTER CLEANING OF NACELLE PRESSURE-REGULATING SHUTOFF-VALVE FILTER BY ULTRASONIC METHOD. OPC BLEED 1 FAIL AND BLEED 1 OVERPRESSURE GOOD IAW AMM 36-11-00 MEL ITEM RESTORED.