What was found
AFT WET AREA BEAM CORRODED AT FR 86 Y-11" (MAJOR REPAIR) (LEVEL 2 CORROSION) BLENDED CORROSION ON BEAM AT FRAME 86 Y-11" IAW E-175 SRM 51-10-03, ORIGINAL THICKNESS .076", MATERIAL LOSS .072", FOUND TO BE OUT OF ALLOWABLE LIMITS IAW E-175 SRM 51-75-16. LOCATED AND DRILLED NEW BEAM PN 170-65669-003 AT FR 86 Y-11 AFT WET AREA IAW E-175 SRM 51-40-02. TOPCOATED FASTENERS ON AFT WET AREA BEAM AT FR 86 Y-11" IAW E-175 SRM 51-23-06 AND ETN-EJ-51-015. APPLIED CIC TO AFT WET AREA BEAM AT FR 86 Y-11" IAW E-175 CPM 51-25-00. REMOVED AND REPLACED BEAM AT FR 86 Y-11 AFT WET AREA IAW E-175 SRM 51-40-08 LEVEL 2 CORROSION