What was found
CORROSION IN AFT WET AREA ON FLOOR SUPPORT BEAM AT FRAME 87-88 Y + 14. (MAJOR REPAIR) (LEVEL 2 CORROSION). BLENDED CORROSION ON AFT WET AREA ON FLOOR SUPPORT BEAM AT FRAME 87-- 88 Y + 14 PER E175 SRM 51-10-03 L=1.0" W=1.0" H=0.050" OUT OF LIMITS PER E175 SRM 53-23-- 10/AD02. LOCATED, DRILLED AND DEBURED NEW AFT WET AREA FLOOR SUPPORT BEAM AT FR87-88 Y+14 IAW E-175 SRM 51-40-02. (PN 170-- 65669-004) . OK TO INSTALL. NSTALLED AFT WET AREA FLOOR SUPPORT BEAM AT FR 87-88 Y+14 IAW E-175 SRM 51-40-08. RESTORED FINISH TO AFT WET AREA ON FLOOR SUPPORT BEAM AT FR87-88 Y+14 IAW E-175 SRM 51-23-06 AND ETN-EJ-51-015.APPLIED CIC TO PAINTED AREA ON FLOOR SUPPORT BEAM AT FRAME 87-88 Y+ 14'' IAW EMBRAER 175 CPM 51-25-00-910-- 001-A. CIC PN: ARDR0X-AV15-LI