What was found
CORROSION FOUND AT CLIP SHEAR ZONE 152 FR 88 STGR 29R (INTERNAL FWD WASTE WATER PANEL) (LEVEL 2 CORROSION) (MAJOR REPAIR) LOCATED AND DRILLED NEW SHEAR CLIP PN# 170-66531-001 IAW EMBRAER 175 SRM 51-40-02. INSTALLED NEW SHEAR CLIP LOCATED AT FR88 AND STR29R IAW EMBRAER 175 SRM 51-40-08. RESTORED FINISH TO SHEAR CLIP LOCATED AT FR88 AND STR29R. IAW ENVOY ETN-EJ-51-015 AND EMBRAER 175 SRM 51-23-06. APPLIED CIC IAW EMBRAER 175 CPM 51-27-00-910-001-A. REMOVED AND REPLACED SHEAR CLIP LOCATED AT FR88 AND STR29R IAW EMBRAER 175 SRM 51-40-08. LEVEL 2 CORROSION