Service difficulty report · Regulator · Emb ERJ170200LR

Difficulty date
December 4, 2025
Submitted
December 10, 2025
Operation
Air carrier
Aircraft
N203NN
Make and model
Emb ERJ170200LR
Aircraft serial
17000473
Aircraft time
28,134 hours, 18,636 cycles
Part
Regulator
Part number
10012463
Condition
Failed
Location
Bleed Sys
Stage of operation
CR
How discovered
V
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

BLEED 2 FAIL AT ALTITUDE. ENG BLEED SYS - XBLD OPERATIVE - M1 BLEED 1 PRESSURE UNSTABLE IN CRUISE 6-47 PSI AND RATE CHANGES OF -250/200 MSG EVENTUALLY CLEARED VIA QRH PROCEDURE INFO TO MTX. INFO NOTED TO MTX MOC 230070. RAR LH ENGINE NAPRSOV HIGH STAGE BLEED VALVE IAW ERJ 175 AMM 36-11-03. OPC GOOD. MEL RESTORED.