What was found
SSI 53-10-027-0392CORROSION - FWD WET AREA - RIGHT TRACK AT FRAME 17 (MAJOR REPAIR) (LEVEL 2 CORROSION). BLENDED CORRODED AREA ON FWD WET AREA RIGHT TRACK AT FRAME 17 PER EMB-175 SRM 51-10-03. BLENDED AREA MEASURES (L=1.2?,W=.8?,H=.025?). ORIGNAL MATERIAL THICKNESS IS .050? REMAINING MATERIAL THICKNESS IS .025? AND IS FOUND TO BE OUT OF ALLOWABLE LIMITS PER EMB-175 SRM 53-10-10/AD01. LOCATED, DRILLED AND ALODINED NEW FWD WET AREA RIGHT SEAT TRACK (PN:170-03263-001) AT FRAME 17 PER EMBRAER 175 SRM 51-40-02, SRM 51-23-04 ETN-EJ-51-008. TOP COATED (PN: ECL-G-16061 PO: 319394) AND CIC (PN: AV30 PO: 341454) NEW FWD WET AREA - RIGHT SEAT AT FRAME 17 PER EMBRAER 175 SRM 51-23-06 ETN-EJ-51-015, CPM 51-27-00-910-001-A. REMOVED AND REPLACED RH SEAT TRACK AT FWD WET AREA FRAME 12- 20 PER EMBRAER 175 SRM 51-40-08. LEVEL 2 CORROSION