What was found
CORROSION FOUND ON CROSSBEAM AT FR 87 (MAJOR REPAIR) (LEVEL 2 CORROSION) BLENDED CORRODED AREA PER SRM 51-10-03 AND ETN-EJ-51-009. AREA MEASURES L= 2.500" X W=.600" X D=.034" & IS FOUND TO BE OUT OF LIMITS PER SRM 51-75-16 AND ET N-EJ-51-009. FABRICATED FILLER, 2 EA SHIMS, & L-ANGLE REPAIR PER ETD2026-170-008942 REV.: . L-ANGLE: . LOCATED & DRILLED 2 EA SHIMS, L-ANGLE REPAIR, & FILLER ON FRAME 84 PER ETD 2026-170-008942 REV.: /. RESTORED FINISH TO 2EA SHIMS, L-ANGLE REPAIR, & FILLER PER SRM 51- 23-04,51-23-05,51-23-06,ETN-EJ-51-015. APPLIED TOPCOAT PER ETD2026-170-008942 REV.: /. REPAIRED CROSSBEAM AT FR 87 R/H SIDE REF ETD2026-170-008942 REV:/ AND ERS-EJ-53MR-5442.