What was found
SAW - DURING PS-2 INSPECTION, MAINTENANCE DISCOVERED NUMEROUS EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT POSITION 10WL IAW JIC 33-51-21-RAI-10010-003. AIRCRAFT WAS RETURNED TO SERVICE. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAW - DURING PS-2 INSPECTION, MAINTENANCE DISCOVERED NUMEROUS EMERGENCY LIGHTS INOP. MAINTENANCE REMOVED AND REPLACED EMERGENCY LIGHT BATTERY PACK AT POSITION 10WL IAW JIC 33-51-21-RAI-10010-003. AIRCRAFT WAS RETURNED TO SERVICE. (M)