What was found
SAW - DURING CPCP-2 INSPECTION MAINTENANCE DISCOVERED THE RIGHT SIDE OF FLOORBEAM 40 CORRODED. MAINTENANCE REMOVED AND REPLACED RIGHT SIDE OF FLOORBEAM 40 IAW SRM 53-61-40. AIRCRAFT WAS RETURNED TO SERVICE. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAW - DURING CPCP-2 INSPECTION MAINTENANCE DISCOVERED THE RIGHT SIDE OF FLOORBEAM 40 CORRODED. MAINTENANCE REMOVED AND REPLACED RIGHT SIDE OF FLOORBEAM 40 IAW SRM 53-61-40. AIRCRAFT WAS RETURNED TO SERVICE. (M)