What was found
FUSELAGE FRAME UNDERFLOOR FS X236.00 CORROSION ON BRACKET SURFACE UNDER FASTENER AT STR. 24S, 25S, AND STR. 26S. CORROSION BEYOND MANUFACTURES LIMITS, PART REPLACEMENT REQUIRED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FUSELAGE FRAME UNDERFLOOR FS X236.00 CORROSION ON BRACKET SURFACE UNDER FASTENER AT STR. 24S, 25S, AND STR. 26S. CORROSION BEYOND MANUFACTURES LIMITS, PART REPLACEMENT REQUIRED.