DURING D CHECK INSPECTION FOUND STINGER CLIP AT STA 616 AND STRINGER 8L WITH 1 FT CRACK. REMOVED AND REPLACED IAW MFG SRM 51-10-1 AND 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D CHECK INSPECTION FOUND STINGER CLIP AT STA 616 AND STRINGER 8L WITH 1 FT CRACK. REMOVED AND REPLACED IAW MFG SRM 51-10-1 AND 51-30-2.