What was found
DURING D CHECK INSPECTION FOUND CORROSION ON FLOORBEAM UPPER CAP AT STA 344 FROM LBL 30 TO RBL 30. REMOVED AND REPLACED DAMMAGED CAP IAW SRM 51-30-2, 51-10-6, 51-10-2 AND 53-10-1.CORROSION LEVEL 1
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING D CHECK INSPECTION FOUND CORROSION ON FLOORBEAM UPPER CAP AT STA 344 FROM LBL 30 TO RBL 30. REMOVED AND REPLACED DAMMAGED CAP IAW SRM 51-30-2, 51-10-6, 51-10-2 AND 53-10-1.CORROSION LEVEL 1