What was found
DURING 24 MONTH INSPECTION FOUND DAMAGE TO CARGO FLOOR SUPPORT STRUCTURE AT STA 797 STR 8R. ALLOWABLE DAMAGE .090 IAW SRM 63-10-1 FIG 5, DAMAGE - .340. REPAIRED DAMAGE IAW SRM 53-10-5, FIG 6.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING 24 MONTH INSPECTION FOUND DAMAGE TO CARGO FLOOR SUPPORT STRUCTURE AT STA 797 STR 8R. ALLOWABLE DAMAGE .090 IAW SRM 63-10-1 FIG 5, DAMAGE - .340. REPAIRED DAMAGE IAW SRM 53-10-5, FIG 6.