What was found
CORROSION ON BS 967 BEAM UPPER CHORD IN 3 LOCATIONS BS967 RBL28 WL208; BS967 RBL42 WL208; AND BS967 RBL49 WL208 ; / [01] REMOVED CORROSION ON BS 967 BEAM UPPER CHORD IN 4 LOCATIONS: AT BS 967 RBL 49 WL 208 IN AN AREA OF 0.6' BY 0.7' BY A MAXIMUM DEPTH OF 0.009'; AT BS 967 RBL 47 WL 208 IN AN AREA OF 0.8' BY 1.1' BY A MAXIMUM DEPTH OF 0.034'; AT BS 967 RBL 40 WL 208 IN AN AREA OF 0.7' BY 0.8' BY A MAXIMUM DEPTH OF 0.008'; AND AT BS 967 RBL 28 WL 208 IN AN AREA OF 0.9' BY 0.9' BY A MAXIMUM DEPTH OF 0.020' PER SRM 51-10-02-0G-0 AND SRM 53-70-51-1A-1. OUT OF LIMITS PER SRM 53-70-51-1A-1.; [[06] REPAIRED DAMAGE ON BS 967 BEAM UPPER CHORD IN 3 LOCATIONS BS 967 RBL 28 WL 208; BS 967 RBL 42 WL 208; AND BS 967 RBL 49 WL 208 PER EA 21-153-03190 (N450WN - ATS (PAE) - REPAIR - BS 967 FLOOR BEAM REPAIR RBL 17 TO RBL 35 AND RBL 45 TO RBL 50) [TTG8Q0099EE6].; [07] VERIFIED CORRECTIVE ACTION 6; [08] UPDATED ITEM #14 P/N 147A5505-6; [09] MEASUREMENT TABLE UPDATED ITEM #14 P/N 147A5505-6