As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
***CORROSION*** ON FLOOR PANEL SUPPORT SPLICE AT AFT CARGO BAY BS887 RBL19 TO LBL7 WL165. / SUPPORT SPLICE FOUND OUT OF LIMITS DUE TO NO LIMITS GIVEN IN SRM REMOVED PART; RECEIVED NEW PART LOCATED PART DRILLED & INSTALLED PER SRM 51-40-02-0G-0 SRM 51-40-05-0G-0; DWG 146A7500; DWG 147A7500