What was found
FLOOR PANEL 221B HAS UPPER SURFACE DAMAGE AND TAB IS BROKEN ON AFT OUTBD EDGE / [01] CORRECT PANEL IS 221BF WITH DAMAGE TO UPPER SURFACE AND TAB AT O/B EDGE NOT 221B.<BR>IDENTIFIED PANEL MATERIAL IAW SRM 53-00-50-0I-1 FIG 2 TABLE 2.<BR>FOUND ALL DAMAGE TO BE OUT OF ALLOWABLE LIMITS IAW SRM 53-00-50-1A-1 PARA 4F.<BR>DAMAGE TO UPPER SURFACE WILL BE REPAIRED IAW SRM 53-00-50-2R-1. DAMAGE TO BROKEN TAB WILL BE REPAIRED IAW SRM 53-00-50-2R-6.<BR>REMOVED ALL INSERTS TO FACILITATE REPAIR IAW SRM 53-00-50-2R-1 PARA 3B.<BR>REMOVED DAMAGE TO UPPER SURFACE PLIES AND DAMAGE TO TAB AT AFT O/B EDGE; CLEANED REPAIR AREA IAW SRM 53-00-50-2R-1 PARA 3C-F AND SRM 53-00-50-2R-6 PARA 3C-E.;[07] FABRICATED CORE SPLICE WITH BMS 8-124 CL4 TY5 G9 LOT# 1287137 PER SRM53-00-50-2R-6 PAR.3F AND TABLE 201. OK TO INSTALL CORE SPLICE.;[12] FABRICATED UPPER SURFACE REPAIR PLIES USING BMS 9-3H2 LOT#1475360-2 IAW SRM 53-00-50-2R-1 PARA 3K.<BR>OK TO INSTALL;[14] INSTALLED REPAIR PLIES USING BMS 8-201TY4 LOT#1464982-6; VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2545 S/N:542505520 IAW SRM 53-00-50-2R-1 PARA 3K-L.