What was found
DURING SCHEDULED C1 CHECK, FOUND AFT ENTRY DOOR EVACUATION SLIDE RELEASE CABLE FRAYED AND GIRT ASSY OUT OF ADJUST. REMOVED AND REPLACED CABLE AND ADJUSTED SLIDE ASSY PER MM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C1 CHECK, FOUND AFT ENTRY DOOR EVACUATION SLIDE RELEASE CABLE FRAYED AND GIRT ASSY OUT OF ADJUST. REMOVED AND REPLACED CABLE AND ADJUSTED SLIDE ASSY PER MM.