What was found
DURING SCHEDULED D-CHECK, FOUND CREASE BEAM WEB UPPER SURFACE CORRODED AT BS 991, LBL 47.5, WL 208. FABRICATED NEW WEB PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D-CHECK, FOUND CREASE BEAM WEB UPPER SURFACE CORRODED AT BS 991, LBL 47.5, WL 208. FABRICATED NEW WEB PER SRM.