What was found
DURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM UPPER CHORD CORRODED AT BS 1016, LBL 10 TO LBL 20. REPAIRED FLOORBEAM UPPER CHORD PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2D CHECK, FOUND FLOORBEAM UPPER CHORD CORRODED AT BS 1016, LBL 10 TO LBL 20. REPAIRED FLOORBEAM UPPER CHORD PER SRM.