What was found
DURING SCHEDULED 1/2D CHECK, FOUND AFT CARGO BIN FLOOR BEAMS CORRODED ( 3 EA ) AT BS'S 795, 813 & 826, LBL3. REPAIRED FLOOR BEAMS PER SWA RA 1-A53-2021.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2D CHECK, FOUND AFT CARGO BIN FLOOR BEAMS CORRODED ( 3 EA ) AT BS'S 795, 813 & 826, LBL3. REPAIRED FLOOR BEAMS PER SWA RA 1-A53-2021.