What was found
DURING SCHEDULED D CHECK, FOUND FLOORBEAM CORRODED AT BS 312, BETWEEN RBL 8 AND LBL 8, WL 208. REPAIRED FLOORBEAM PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D CHECK, FOUND FLOORBEAM CORRODED AT BS 312, BETWEEN RBL 8 AND LBL 8, WL 208. REPAIRED FLOORBEAM PER SRM.