What was found
DURING SCHEDULED 1/2D CHECK, FOUND L1 DOOR EVACUATION SLIDE ATTACHED BRACKET CORRODED. REMOVED AND REPLACED BRACKET PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2D CHECK, FOUND L1 DOOR EVACUATION SLIDE ATTACHED BRACKET CORRODED. REMOVED AND REPLACED BRACKET PER SRM.