What was found
DURING SCHEDULED 1/4D CHECK, FOUND VERTICAL BEAM WEB CRACKED .25 INCH LONG AT BS 181.5, WL 182 AND RBL 17.1. REPAIRED WEB PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/4D CHECK, FOUND VERTICAL BEAM WEB CRACKED .25 INCH LONG AT BS 181.5, WL 182 AND RBL 17.1. REPAIRED WEB PER SRM.