What was found
DURING SCHEDULED 1/2D CHECK, FOUND FWD ENTRY DOOR FWD CUTOUT FRAME VERTICAL WEB CRACKED AT BS 303.9, STR 16R. REMOVED AND REPLACED VERTICAL WEB PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2D CHECK, FOUND FWD ENTRY DOOR FWD CUTOUT FRAME VERTICAL WEB CRACKED AT BS 303.9, STR 16R. REMOVED AND REPLACED VERTICAL WEB PER SRM.