What was found
DURING SCHEDULED 1/4D CHECK, FOUND STRINGER SPLICES CRACKED (4 EA) AT BS 663.75, STR 2R, 2L, 3R AND 3L. REMOVED AND REPLACED STR SPLICES PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/4D CHECK, FOUND STRINGER SPLICES CRACKED (4 EA) AT BS 663.75, STR 2R, 2L, 3R AND 3L. REMOVED AND REPLACED STR SPLICES PER SRM.