What was found
AFTER DEPARTURE AN ELECTRICAL FUME WAS NOTICED, CABIN CREW CONFIRMED FUME. NO CB'S TRIPPED, AC AND DC LOADS ALL NORMAL. FUMES DIMMISHED BUT NOT ELIMINATED. FOUND BLUE FLUID FROM FWD LAV LEAKING AT PRESS FILL. FOUND LOWER ENTRY LIGHT SHORTED OUT DUE TO LAV SPRAY. REMOVED AND REPLACED BULB PER MM. FOUND FWD LAV PRESS FILL ATTACHMENT STUDS ON TANK LOOSE. REMOVED AND REPLACED FWD LAV PRESS FILL ATTACHMENT SEAL AND TIGHTENED STUDS PER MM