What was found
DURING SCHEDULED C2 CHECK, FOUND 1 INCH LONG CRACK AT KEELBEAM CENTER PANEL, BS 685, STRINGER 28L. REPAIRED KEEL BEAM PANEL PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C2 CHECK, FOUND 1 INCH LONG CRACK AT KEELBEAM CENTER PANEL, BS 685, STRINGER 28L. REPAIRED KEEL BEAM PANEL PER SRM.