What was found
DURING SCHEDULED D CHECK, FOUND MANUAL GEAR EXTENSION ACCESS DOOR AND FLOOR STRUCTURE AT BS 243 TO BS 253, RBL 6 TO RBL 12, CORRODED. REPAIRED FLOOR STRUCTURE PER SRM AND BAC DRAWING.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D CHECK, FOUND MANUAL GEAR EXTENSION ACCESS DOOR AND FLOOR STRUCTURE AT BS 243 TO BS 253, RBL 6 TO RBL 12, CORRODED. REPAIRED FLOOR STRUCTURE PER SRM AND BAC DRAWING.