What was found
DURING SCHEDULED D-CHECK, FOUND AFT CARGO DOOR CUTOUT FRAME UPPER CLOSE OUT WEB LOWER AREA, CORRODED. REMOVED AND REPLACED DOOR CUTOUT FRAME WEB PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D-CHECK, FOUND AFT CARGO DOOR CUTOUT FRAME UPPER CLOSE OUT WEB LOWER AREA, CORRODED. REMOVED AND REPLACED DOOR CUTOUT FRAME WEB PER SRM.