What was found
DURING SCHEDULED D CHECK, FOUND FLOORBEAM WEB AT BS 1016, LBL 1 TO RBL 37, CORRODED. REMOVED AND REPLACED FLOORBEAM WEB SECTION PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D CHECK, FOUND FLOORBEAM WEB AT BS 1016, LBL 1 TO RBL 37, CORRODED. REMOVED AND REPLACED FLOORBEAM WEB SECTION PER SRM.