What was found
DURING SCHEDULED 1/4D CHECK, FOUND R1 DOOR AFT SIDE FRAME AT THIRD STOP FITTING CRACKED. REPAIRED FRAME SECTION PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/4D CHECK, FOUND R1 DOOR AFT SIDE FRAME AT THIRD STOP FITTING CRACKED. REPAIRED FRAME SECTION PER SRM.