What was found
DURING SCHEDULED 1/2D CHECK, FOUND FWD ENTRY DOOR AFT FRAME NEAR 4TH STOP FITTING FROM BOTTOM, CRACKED. REPAIRED FRAME SECTION PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/2D CHECK, FOUND FWD ENTRY DOOR AFT FRAME NEAR 4TH STOP FITTING FROM BOTTOM, CRACKED. REPAIRED FRAME SECTION PER SRM.