What was found
DURING SCHEDULED D-CHECK, FOUND FLOORBEAM SHEAR WEB FROM BS 947 TO BS 1006, RBL 45, CORRODED. REMOVED AND REPLACED WEB PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D-CHECK, FOUND FLOORBEAM SHEAR WEB FROM BS 947 TO BS 1006, RBL 45, CORRODED. REMOVED AND REPLACED WEB PER SRM.