What was found
DURING SCHEDULED 1/4D CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE GIRT BAR AFT FLOOR FITTING BROKEN. REMOVED AND REPLACED FITTING PER MM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/4D CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE GIRT BAR AFT FLOOR FITTING BROKEN. REMOVED AND REPLACED FITTING PER MM.