What was found
DURING SCHEDULED 1/4D CHECK, FOUND LONGITUDINAL FLOORBEAM CORRODED AT BS 773, RBL 3 & RBL 14. REPAIRED FLOORBEAM PER SWA EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 1/4D CHECK, FOUND LONGITUDINAL FLOORBEAM CORRODED AT BS 773, RBL 3 & RBL 14. REPAIRED FLOORBEAM PER SWA EA.