What was found
DURING SCHEDULED D CHECK, FOUND FUSELAGE FLOORBEAM CORRODED AT BS 328, BETWEEN RBL 45 TO RBL 52, WL 208. REPAIRED FLOORBEAM PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D CHECK, FOUND FUSELAGE FLOORBEAM CORRODED AT BS 328, BETWEEN RBL 45 TO RBL 52, WL 208. REPAIRED FLOORBEAM PER SRM.