What was found
DURING SCHEDULED D CHECK, FOUND FUSELAGE FLOORBEAM CORRODED AT BS 294, RBL 25, WL 208. REPAIRED FLOORBEAM PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED D CHECK, FOUND FUSELAGE FLOORBEAM CORRODED AT BS 294, RBL 25, WL 208. REPAIRED FLOORBEAM PER SRM.