What was found
DURING SCHEDULED 18Y CHECK, FOUND CREASE BEAM WEB CORRODED AT BS 400 TO BS 440, RBL 65 TO RBL 70.5. REMOVED AND REPLACED FLOORBEAM WEB PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 18Y CHECK, FOUND CREASE BEAM WEB CORRODED AT BS 400 TO BS 440, RBL 65 TO RBL 70.5. REMOVED AND REPLACED FLOORBEAM WEB PER SRM.