What was found
DURING SCHEDULED 10Y CHECK, FOUND FLOORBEAM UPPER CHORD CORRODED AT BS 270, LBL 11 TO RBL 11. REMOVED AND REPLACED FLOORBEAM CHORD PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 10Y CHECK, FOUND FLOORBEAM UPPER CHORD CORRODED AT BS 270, LBL 11 TO RBL 11. REMOVED AND REPLACED FLOORBEAM CHORD PER SRM.