What was found
DURING SCHEDULED 8Y CHECK, FOUND CREASE BEAM WEB CORRODED AT BS 986 TO BS 997, RBL 48. REMOVED AND REPLACED WEB PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 8Y CHECK, FOUND CREASE BEAM WEB CORRODED AT BS 986 TO BS 997, RBL 48. REMOVED AND REPLACED WEB PER SRM.