What was found
DURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM WEB CORRODED BETWEEN BS 1006 AND BS 1016, LBL 38 AND LBL 39. REMOVED AND REPLACED WEB PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 16Y CHECK, FOUND FLOORBEAM WEB CORRODED BETWEEN BS 1006 AND BS 1016, LBL 38 AND LBL 39. REMOVED AND REPLACED WEB PER SRM.