What was found
DURING SCHEDULED 20Y CHECK, FOUND R1 DOOR AFT CUTOUT FRAME CRACKED AT SECOND STOP FITTING. REPAIRED FRAME PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 20Y CHECK, FOUND R1 DOOR AFT CUTOUT FRAME CRACKED AT SECOND STOP FITTING. REPAIRED FRAME PER SRM.