What was found
DURING SCHEDULED MV2 CHECK, FOUND FLOORBEAM SUPPORT CORRODED AT BS 270, RBL 12. REMOVED AND REPLACED BEAM PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED MV2 CHECK, FOUND FLOORBEAM SUPPORT CORRODED AT BS 270, RBL 12. REMOVED AND REPLACED BEAM PER SRM.