DURING SCHEDULED 12Y CHECK, FOUND BEAR STRAP SKIN CORRODED AT BS 846, STR. 26R. REPAIRED SKIN PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 12Y CHECK, FOUND BEAR STRAP SKIN CORRODED AT BS 846, STR. 26R. REPAIRED SKIN PER SRM.