What was found
DURING SCHEDULED 16Y CHECK, FOUND AFT GALLEY DOOR CREASE BEAM CORRODED BETWEEN BS 947 TO BS 1008. REMOVED AND REPLACED BEAM PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 16Y CHECK, FOUND AFT GALLEY DOOR CREASE BEAM CORRODED BETWEEN BS 947 TO BS 1008. REMOVED AND REPLACED BEAM PER SRM.