What was found
DURING SCHEDULED 8Y CHECK, FOUND FWD CABIN CREASE BEAM CORRODED BETWEEN BS 295 TO BS 328, RBL 56. REPAIRED BEAM PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 8Y CHECK, FOUND FWD CABIN CREASE BEAM CORRODED BETWEEN BS 295 TO BS 328, RBL 56. REPAIRED BEAM PER SRM.