What was found
DURING SCHEDULED SPV, FOUND AFT CARGO DOOR CUTOUT FRAME CORRODED AT BS 764. REMOVED AND REPLACED FRAME SECTION PER SRM.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED SPV, FOUND AFT CARGO DOOR CUTOUT FRAME CORRODED AT BS 764. REMOVED AND REPLACED FRAME SECTION PER SRM.