What was found
DURING SCHEDULED 16Y CHECK, FOUND AFT CARGO LONGITUDINAL FLOORBEAM CORRODED AT BS 731D, LBL 3. REPAIRED BEAM PER SRM & EA.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED 16Y CHECK, FOUND AFT CARGO LONGITUDINAL FLOORBEAM CORRODED AT BS 731D, LBL 3. REPAIRED BEAM PER SRM & EA.