What was found
DURING SCHEDULED SPV CHECK, FOUND CREASE BEAM WEB CORRODED BETWEEN BS 837 TO BS 846, STR 18R. REPAIRED WEB PER BAC DWG.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED SPV CHECK, FOUND CREASE BEAM WEB CORRODED BETWEEN BS 837 TO BS 846, STR 18R. REPAIRED WEB PER BAC DWG.